Growing Automation & Controls
INKBIRD C226T
Growing-condition measurement or control
Sensors and controllers measure or act on devices through supported interfaces.
Current per recorded source Version unknown

Key specifications
- Sensors and measured quantities
- Temperature
- Controlled equipment
- Heating and cooling equipment
- Calibration
- Calibration adjustment supported
- Brand
- INKBIRD
- Model
- C226T
- Generation / revision
- Unknown
- Regional version
- Unknown; confirm exact plug, voltage and SKU
- Classification
- Growing Automation & Controls
- Technical route
- Growing-condition measurement or control (editorial classification)
- Product status
- current — Published official catalog record; at least one variant available=true. This is not a stock or delivery guarantee.
- Verified
- 2026-11-25
Technical parameters and evidence
Unknown means unverified. The source column distinguishes manufacturer declarations from other evidence. Conflicting values remain in the source record.
| Parameter | Value | Evidence and date |
|---|---|---|
| Physical interfaces | Unknown | No verified value |
| Communications protocol | Unknown | No verified value |
| Sensors and measured quantities | Temperature | Temperature Controller C226T manufacturer declaration · 2026-11-25 catalog description |
| Controlled equipment | Heating and cooling equipment | Temperature Controller C226T manufacturer declaration · 2026-11-25 catalog description |
| Calibration | Calibration adjustment supported | Temperature Controller C226T manufacturer declaration · 2026-11-25 catalog description |
| Compatibility conditions | Unknown | No verified value |
| Power supply | Unknown | No verified value |
| Device ports | Unknown | No verified value |
Configuration and compatibility
- Plug Type: US; EU; UK — options.Plug Type
The load rating changes; verify the work the outlet must do
INKBIRD lists the same three control modes as the C216T, with temperature alarms, calibration adjustment and a refrigeration delay. The C226T product page gives a 16 A maximum and lists 1,800 W at 120 VAC and 3,680 W at 230 VAC. Read those as distinct manufacturer ratings for the documented conditions. Do not extrapolate a rating for a different plug, voltage, relay load type or market.
The manufacturer also lists an IP67 probe for both models. That is evidence of the documented probe enclosure rating, not proof of a different sensor, a replaceable connector or interchangeable probes. Start from the requirement for one compatible load and check how the connected device restarts. A higher nameplate limit has little decision value for a load already within the C216T's supported envelope.
The voltage-specific examples matter when reading the headline maximum. The source's 1,800 W at 120 VAC corresponds to 15 A by simple division for this rating example. That arithmetic does not authorize substituting the listed 16 A headline for the separate 120 VAC wattage value. Confirm the voltage, actual load class, regional outlet and device limits together. Ask the manufacturer when any of the scope is unclear.
Choose this shortlist branch when the C216T's lower documented rating rules it out and the specific regional equipment combination is confirmed. For two separately controlled loads, compare the documented dual-relay arrangement on the ITC-308 family. Timing and alarm features alone cannot justify the larger electrical rating for a different operating requirement.
Compare the documented setup with INKBIRD C216T or INKBIRD ITC-308.
Keep the exact electrical rating separate from sensing differences
Consider the C226T where the C216T’s documented 120 V rating excludes an appliance and the exact C226T variant and load are supported. The larger rating does not establish closer temperature control or a more serviceable probe. Check controller and load behavior after an outage and obtain the manufacturer’s load-specific limits before making unattended use a requirement. A separately controlled heating and cooling setup belongs in a dual-output comparison.
| Controller | Published rating | Source |
|---|---|---|
| C226T | 1,800 W at 120 VAC; 3,680 W at 230 VAC; listed maximum 16 A | C226T specifications |
| C216T | 1,200 W at 120 VAC; 2,200 W at 220 VAC; listed maximum 10 A | C216T specifications |
Use the rating shown for the exact plug and supply. Both source pages list the same three operating modes and an IP67 probe. Probe interchangeability, load-specific starting limits and whole-device water resistance are unverified. Checked November 27, 2026.
Additional manufacturer evidence
- INKBIRD C226T operating modes and electrical specifications — Manufacturer Specification. Main Features and Specifications. Three modes, IP67 probe, 16 A listed maximum, 1,800 W at 120 VAC and 3,680 W at 230 VAC. Region and load conditions still apply. .
- INKBIRD shared C216T and C226T manual listing — Manufacturer Support. Manual link identifies both model IDs. Numeric ratings in prose use exact product specification pages. .
Known limits
- Manufacturer declarations; no independent testing by GROWVELIA.
- Unknown fields are unverified, not zero.
- Confirm the exact regional SKU and hardware revision with its manual before purchase or connection.
- Regional voltage, plug, relay load and Wi-Fi options must be checked; series options are not separate model counts.
Official sources
- Temperature Controller C226T — manufacturer product data; verified 2026-11-25
Sources document the exact model and test conditions where available.
Conflicts and missing information
No conflict recorded in the reviewed evidence; this is not proof that all sources agree.
Missing technical fields: Physical interfaces, Communications protocol, Compatibility conditions, Power supply, Device ports. Missing identity fields: version, region.
How to read evidence coverage
Coverage describes the record, independent of product performance. Not Applicable fields are excluded from the denominator.
- Documented
- A source records the value.
- Not Provided
- An applicable field has no value in the record.
- Not Applicable
- The field is outside the applicable scope.
- Conflicting Data
- Sources disagree and the value is withheld from dependent decisions.
- Unknown
- The value, revision or market status could not be established.