Growing Automation & Controls
AC Infinity CONTROLLER 69
uis environmental controller
Sensors and controllers measure or act on devices through supported interfaces.
Unknown CTR69A

Key specifications
- Communications protocol
- Bluetooth
- Sensors and measured quantities
- Temperature and humidity; VPD displayed
- Device ports
- 4 ports
- Physical interfaces
- UIS device ports
- Brand
- AC Infinity
- Model
- CONTROLLER 69
- Generation / revision
- CTR69A
- Regional version
- Unknown; confirm exact plug, voltage and SKU
- Classification
- Growing Automation & Controls
- Technical route
- uis environmental controller (editorial classification)
- Product status
- unknown — Current sale status not established by this technical document.
- Verified
- 2026-11-25
Technical parameters and evidence
Unknown means unverified. The source column distinguishes manufacturer declarations from other evidence. Conflicting values remain in the source record.
| Parameter | Value | Evidence and date |
|---|---|---|
| Physical interfaces | UIS device ports | AC Infinity controllers comparison manufacturer declaration · 2026-11-25 Technical specifications |
| Communications protocol | Bluetooth | AC Infinity controllers comparison manufacturer declaration · 2026-11-25 Technical specifications |
| Sensors and measured quantities | Temperature and humidity; VPD displayed | AC Infinity controllers comparison manufacturer declaration · 2026-11-25 Technical specifications |
| Controlled equipment | Compatible UIS equipment with independent port programming | AC Infinity controllers comparison manufacturer declaration · 2026-11-25 Technical specifications |
| Calibration | Unknown | No verified value |
| Compatibility conditions | UIS devices and adapters; exact adapter compatibility must be checked | AC Infinity controllers comparison manufacturer declaration · 2026-11-25 Technical specifications |
| Power supply | Unknown | No verified value |
| Device ports | 4 ports | AC Infinity controllers comparison manufacturer declaration · 2026-11-25 Comparison Device Ports |
| VPD-triggered control (separate from display) | false | AC Infinity Controller 69 programming overview manufacturer programming documentation · 2026-11-25 Programs and VPD Mode: PRO & PRO+ models only |
| Output levels | 10 levels | AC Infinity controllers comparison manufacturer declaration · 2026-11-25 Comparison Precise Speeds / Levels |
Configuration and compatibility
No additional configuration verified. Confirm exact hardware, power supply and regional SKU against its manual.
Use a documented trigger rather than a display label
The standard CONTROLLER 69 archive supports four UIS ports, local Bluetooth and temperature and humidity sensing. A reader can plan separate supported devices for the ports and assign an actual control requirement to each. The source distinguishes the displayed VPD quantity from a VPD-triggered program.
Consider this controller when compatible loads and supported triggers already cover the task. If a device must respond to VPD itself, compare the 69 PRO programming and keep compatibility of the connected accessory separate. Bluetooth access is not a promise of remote internet operation or a restart behavior.
Treat the visible VPD value as a reading when listing actions
Identify which supported UIS device needs to act and what documented condition should trigger it. A standard 69 can display VPD while the required VPD-trigger program remains outside its recorded scope. Compare the 69 PRO if that trigger is mandatory, and verify the accessory independently.
Known limits
- Manufacturer documentation; no GROWVELIA hands-on test.
- Do not infer missing specifications or compatibility.
- Capacity, fixture output and coverage are not measured harvest results.
- VPD is derived, not a separate physical sensor. A matching connector alone does not establish third-party compatibility.
Official sources
- AC Infinity controllers comparison — manufacturer documentation; verified 2026-11-25
- AC Infinity Controller 69 programming overview — manufacturer programming documentation; verified 2026-11-25
- AC Infinity Controller 69 Pro programming overview — Manufacturer documentation; verified 2026-11-26
Sources document the exact model and test conditions where available.
Conflicts and missing information
clarification: VPD display is separate from VPD-triggered control. The official programming overview limits VPD mode to PRO and PRO+; the original conflict observations are retained below as evidence history.
- AC Infinity Controller 69: Comparison shows VPD for all; overview says VPD triggers only PRO/PRO+. VPD display does not imply VPD trigger support.
Missing technical fields: Calibration, Power supply. Missing identity fields: region.
How to read evidence coverage
Coverage describes the record, independent of product performance. Not Applicable fields are excluded from the denominator.
- Documented
- A source records the value.
- Not Provided
- An applicable field has no value in the record.
- Not Applicable
- The field is outside the applicable scope.
- Conflicting Data
- Sources disagree and the value is withheld from dependent decisions.
- Unknown
- The value, revision or market status could not be established.