Comparing documented fixture performance
Select fixtures by exact identity
Start with the labels from the fixtures or the precise variants in the specification you are evaluating. Select two to four distinct records. Product model suffixes, regional versions and revisions can change the evidence available for an apparently familiar name. A rated electrical input can be documented even when the same record has no usable photon claim. The page shows fields independently so one well-documented parameter does not lend certainty to another.
The inputs are database products. If you want to compare a map you took yourself, use the coverage tool. Manual PPFD readings do not replace catalog records here. The evidence sidebar can provide context for a product but does not add a selected fixture to the comparison.
Read the three photon and electrical quantities separately
Input watts describe an electrical rate. PPF describes total emitted photosynthetic photon flux in µmol/s. Dividing declared PPF by declared input watts gives µmol/J, a numerical efficacy ratio whose scope stays with those declarations. The result does not create an independent test or replace documented PPE. Confirm that both values refer to the same operating condition if you need to use the ratio in a decision. For example, an output claimed at full power should not be paired with a low dimmer input reading to estimate the full-power efficacy.
PPFD describes photons arriving per area per second. A high fixture PPF does not put the same amount of light everywhere and cannot establish an adequate PPFD at every shelf position. Even a higher catalog efficacy remains a fixture-level statement. A system may need two fixtures, mount closer or run at a different setting to deliver the target coverage. When the task is to light a specific area, include the distance, map geometry, sampling and power mode in the comparison before drawing a conclusion.
Follow the evidence status before reading any apparent winner
A row may show a known claim for each product without making the claims directly comparable. Source scope, test geometry, distance or terminology may differ. A comparative claim about PPFD needs matching documented measurement conditions. Leave a metric undecided if its measurement basis cannot be established. In particular, never treat a model missing a value as supplying zero photons or consuming zero power.
Open the conflict evidence when a source field disagrees with another declaration. Quarantined values remain visible for provenance where available; the comparison does not use those values in the declared ratio. A published efficacy in one source does not give you permission to reverse-calculate a missing PPF when the inputs are absent or disputed. Check a rate against the source units before copying a ratio to a spreadsheet, and retain exposure and operating context alongside that export.
Match the comparison to a purchase or installation decision
If the device shares a circuit with a cabinet and pump, credible input power can answer a budget question before you have optical evidence. If the requirement is an edge PPFD across a particular rack, reserve the decision until you have a useful map. Where lamps serve different purposes or optics, compare the evidence first and then map the application. A small difference in PPF/W is often less actionable than an unresolved installation issue, such as whether one fixture can occupy the necessary position.
Use an independent, scoped measurement when the available source figures cannot support the desired comparison. Record fixture identity, dimmer setting, distance and the measuring method. That evidence can be interpreted alongside the catalog. This page does not accept new product specifications or confirm optical performance from an unreviewed map.
Worked examples
Scenario values are illustrative. Model examples use the identified product records and their documented limits.
Two older revisions with quarantined optical claims
Illustrative Scenario
The illustrative decision is between the documented Spider Farmer SF1000 and SF2000 records.
| Input | Value |
|---|---|
| Select two to four real product records | Spider Farmer SF1000 (2026), Spider Farmer SF2000 (2026) |
How the result follows
The catalog preserves model power but no usable PPF for either ratio. Both derived entries must therefore be null.
What the tool returned
Calculated
| Result field | Observed value |
|---|---|
| Products | 2 |
| Derived Ratios | 0 |
| Declared Ratios 1 · Derived Declared Ppe | Unknown |
What to do with the result
Power can inform one part of an electrical brief; efficacy and coverage remain unresolved.
Scope of this example
Do not pick a side from the quarantined claims.
Two SANSI fixtures with usable source values
Illustrative Scenario
Compare the recorded PAR20 10W and BR30 24W for a hypothetical decision.
| Input | Value |
|---|---|
| Select two to four real product records | SANSI PAR20 10W, SANSI BR30 24W |
How the result follows
From the declarations, 16.8 ÷ 10 = 1.68 and 36.2 ÷ 24 ≈ 1.5083 µmol/J.
What the tool returned
Calculated
| Result field | Observed value |
|---|---|
| Products | 2 |
| Derived Ratios | 2 |
| Declared Ratios 1 · Derived Declared Ppe | 1.68 |
| Declared Ratios 2 · Derived Declared Ppe | 1.508333333 |
What to do with the result
Both ratios are available for auditing. The larger declared output can coexist with a lower declared ratio.
Scope of this example
The ratio cannot establish the PPFD distribution at your mounting height.
One available ratio in a mixed comparison
Illustrative Scenario
Compare Soltech Highland with Barrina TR40A3 in an illustrative shelf selection.
| Input | Value |
|---|---|
| Select two to four real product records | Barrina TR40A adjustable, Soltech Highland |
How the result follows
The Highland record provides 40 µmol/s and 30 W. The Barrina record does not provide a usable PPF. Only one ratio, around 1.3333, can be derived.
What the tool returned
Calculated
| Result field | Observed value |
|---|---|
| Products | 2 |
| Derived Ratios | 1 |
| Declared Ratios 2 · Derived Declared Ppe | 1.333333333 |
| Declared Ratios 1 · Derived Declared Ppe | Unknown |
What to do with the result
The absence of a second ratio prevents a two-model efficacy conclusion.
Scope of this example
Track mount geometry and seek measurements before selecting a shelf solution.
Three sourced cases with one missing input set
Illustrative Scenario
Use ViparSpectra P1000, SANSI BR30 36W and Soltech Vita to explore mixed evidence coverage.
| Input | Value |
|---|---|
| Select two to four real product records | ViparSpectra P1000, SANSI BR30 36W, Soltech Vita |
How the result follows
No source-scoped PPF is usable for P1000 here. The other two figures are 65.6 ÷ 36 and 25.95 ÷ 20.
What the tool returned
Calculated
| Result field | Observed value |
|---|---|
| Products | 3 |
| Derived Ratios | 2 |
| Declared Ratios 2 · Derived Declared Ppe | 1.822222222 |
| Declared Ratios 3 · Derived Declared Ppe | 1.2975 |
What to do with the result
Two ratios are available for separate evidence checks, not a three-model ranking.
Scope of this example
The applications and optics can differ despite sharing the same computed unit.
Four fixtures with asymmetric provenance
Illustrative Scenario
For a hypothetical comparison use SF1000D, SANSI A21 15W, Soltech Grove and Barrina T1X3.
| Input | Value |
|---|---|
| Select two to four real product records | SANSI A21 15W (C21GL-DE26-15W documented), Barrina T1X3, Spider Farmer SF1000D (2026), Soltech Grove |
How the result follows
The catalog supports the A21 division 27.2 ÷ 15 and Grove division 17 ÷ 11. SF1000D and T1X3 cannot supply a usable ratio.
What the tool returned
Calculated
| Result field | Observed value |
|---|---|
| Products | 4 |
| Derived Ratios | 2 |
| Declared Ratios 1 · Derived Declared Ppe | 1.813333333 |
| Declared Ratios 4 · Derived Declared Ppe | 1.545454545 |
What to do with the result
The A21's electrical compatibility evidence is separate from its declared photon ratio.
Scope of this example
Keep product restrictions visible even where a different field can be calculated.
Read next
Related original case studies
- SF1000D and SF1000 Need a Version-Specific Identity Check
Demonstrates why suffix and revision identity take priority over family-name comparisons.
- P1000 and XS1500 Pro Separate a Power Budget From a Light Budget
Separates a known electrical budget from missing optical evidence.
- A SANSI Photon Ratio Is an Audit, Not a Second Test
Explains what checking manufacturer PPF divided by watts does and does not establish.
Technical guides
- Understanding Grow Light Efficiency
Shows how to interpret the derived ratio beside the manufacturer’s declared PPE.
- Manufacturer vs Independent Grow Light Measurements
Explains how to judge whether measurements share the same test scope.
Sources and equipment records
References for the method
Related equipment evidence
- Spider Farmer SF1000 (2026)
Read the exact version, region and official field sources before using a declared spec. Status in the record is unknown.
- Spider Farmer SF2000 (2026)
Read the exact version, region and official field sources before using a declared spec. Status in the record is unknown.
- SANSI PAR20 10W
Read the exact version, region and official field sources before using a declared spec. Status in the record is current.