DLI Calculator

Integrate measured or declared PPFD over a day at a single receiving location.

Growers checking a steady lamp, timed dimming plan, mixed daylight schedule or recorded interruption.

Inputs
PPFD and duration for each non-overlapping period
Results
Per-period contribution and total DLI

Estimate daily light integral under constant PPFD.

Result

Enter both inputs to calculate.

Instructions

Measure PPFD at plant height and enter daily lighting duration from 0 to 24 hours. Zero is valid; empty or negative inputs are not.

Calculation basis

DLI = PPFD × hours × 0.0036, expressed in mol/m²/day. Assumes constant intensity; excludes unentered sunlight. Results are rounded to two decimals, not a crop recommendation.

Source: Apogee Instruments

Related case

A constant-light DLI scenario

Back to Tools

Multiple light periods

Integrate disjoint constant-PPFD periods across a day. Single-period calculations above synchronize to this editor for saving and export.

Calculation method

Total DLI = Σ(PPFD × hours × 0.0036); total non-overlapping duration must not exceed 24 hours.

Scope

Each period is a constant-average approximation. Do not count sunlight and combined measured PPFD twice.

Adding daily light across separate intervals

Turn the schedule into a dose

A single PPFD reading describes the rate of photon arrival at one moment. The daily light integral is the number of moles received per square meter across a day. When the fixture runs steadily and the setting stays fixed, the quick calculator uses one intensity and one duration. When the output changes or daylight contributes, use the period grid to keep track of the different exposures.

Schedule the rows on paper before moving to the editor. The tool checks that their durations fit within one day, but it receives no start and stop times and cannot detect two rows occupying the same hour. For a morning period with daylight and lamps running together, enter their combined observed or explicitly assumed intensity once. A separate daylight-only contribution would double-count that span if included again. If records cover only part of a day, document that distinction before calling the sum a full day.

Use average readings from the same surface

Choose a representative average for each interval and keep sensor height and position consistent. If an interval had cloud changes, averaging several readings weighted by the time they represent gives a better input than the brightest reading. A percent dimmer setting or a fixture specification in watts is not the PPFD delivered to the leaves. Record a measured dark period as zero if you want the rows to cover the full clock day. An unknown interval is a missing observation, so do not enter it as darkness.

Each contribution is the interval PPFD multiplied by hours and 0.0036. The factor converts 3,600 seconds per hour and divides by one million µmol per mol. The Results table shows the contribution from each period and a daily sum. Check the total entered hours first, then identify intervals that contribute unexpectedly much or little. A result of 0.00 can arise from zero exposure as well as rounding a very small dose.

Read a daily total together with its schedule

Two schedules may produce the same daily integral while exposing the crop at different rates and times. The arithmetic does not decide that a crop responds identically to them or endorse a particular light-dark cycle. To compare fixture placement use a spatial map, and calculate separate daily exposures for different positions if uniformity matters. For outages, run the schedule as it actually occurred alongside the plan, and keep any agriculture decision separate from estimating the missed dose.

Worked examples

Scenario values are illustrative. Model examples use the identified product records and their documented limits.

Steady under-shelf lamp

Illustrative Scenario

An illustrative fixture delivers 180 µmol/m²/s for 14 hours.

Non-overlapping daily light periods
RowPPFD (µmol/m²/s)Hours
118014

How the result follows

180 × 14 × 0.0036 equals 9.072 mol/m²/day.

What the tool returned

Calculated

Verified output
Result fieldObserved value
Total hours14
Total DLI (mol/m²/day)9.072

What to do with the result

Use the quick form for a steady interval; the period list can record the same value.

Scope of this example

Measured or assumed intensity is specific to the receiving surface.

A brighter start, a gentler finish

Illustrative Scenario

An illustrative schedule runs at 300 for six hours and 120 for ten hours.

Non-overlapping daily light periods
RowPPFD (µmol/m²/s)Hours
13006
212010

How the result follows

Contributions are 6.48 and 4.32, giving 10.8 mol/m²/day.

What the tool returned

Calculated

Verified output
Result fieldObserved value
Total hours16
Total DLI (mol/m²/day)10.8
Rows 2 · Dli4.32

What to do with the result

The shorter, brighter block contributes more photons.

Scope of this example

Equal clock blocks are unnecessary; each reading is weighted by its own duration.

Window plus lamp overlap

Illustrative Scenario

A two-hour illustrative combined period of 350 is followed by eight lamp-only hours at 160 and a confirmed fourteen-hour dark period.

Non-overlapping daily light periods
RowPPFD (µmol/m²/s)Hours
13502
21608
3014

How the result follows

Add 2.52, 4.608 and zero to obtain 7.128 mol/m²/day.

What the tool returned

Calculated

Verified output
Result fieldObserved value
Total hours24
Total DLI (mol/m²/day)7.128

What to do with the result

Use the combined intensity once for the overlap and keep darkness as an explicit record.

Scope of this example

No unrecorded daytime intervals can be inferred from this schedule.

Two hours lost to an outage

Illustrative Scenario

A planned illustrative twelve-hour block at 240 instead runs for ten hours; two interrupted hours have zero exposure.

Non-overlapping daily light periods
RowPPFD (µmol/m²/s)Hours
124010
202

How the result follows

240 × 10 × 0.0036 is 8.64; a full twelve hours would have supplied 10.368.

What the tool returned

Calculated

Verified output
Result fieldObserved value
Total hours12
Total DLI (mol/m²/day)8.64

What to do with the result

The known missed exposure is 1.728 mol/m² for this interval.

Scope of this example

The comparison does not justify extending the next day's schedule.

Changing light during inspection

Illustrative Scenario

An illustrative logged window has one hour at 100, three at 225 and six at 50.

Non-overlapping daily light periods
RowPPFD (µmol/m²/s)Hours
11001
22253
3506

How the result follows

Multiply each PPFD by its own hours to obtain 0.36 + 2.43 + 1.08 = 3.87.

What the tool returned

Calculated

Verified output
Result fieldObserved value
Total hours10
Total DLI (mol/m²/day)3.87

What to do with the result

The plain mean of the three intensity numbers would overemphasize the highest log entry.

Scope of this example

Keep a separate record for the rest of the clock day if it was not included.

Read next

Sources and equipment records