Two Headline Numbers Cannot Supply a Missing Pump Curve

An illustrative owner has only headline maxima for a candidate and considers using a default line to obtain a selection result.

Evidence basis: Illustrative Scenario / Worked Example — invented declared curves, not real pump tests.

Updated

A default line can conceal the missing evidence

The owner has a maximum-flow statement and a maximum-head statement but no adequate curve for the candidate. It considers drawing a straight line between them because the calculator needs points. That would produce numbers, but it would not produce source evidence.

This case uses no actual candidate pump and invents no replacement SKU. Its numerical partial curve is a separate original illustration, not an interpretation of a manufacturer's headline specifications. The decision is how to preserve the missing-data boundary while still recognizing that a genuinely scoped partial curve can sometimes answer a limited question.

The owner should distinguish no applicable curve, a curve with an unidentified source and an applicable curve covering only part of the head domain. Those situations need different records. None is repaired merely by entering a plausible-looking source label or accepting default samples.

The missing-source test should fail

The first actual T12 run supplies placeholder points but leaves curveSource blank. The engine returns Insufficient Data. This tests the current source requirement, not the physical behavior of a pump.

The input contract requires identification of the curve source and operating scope. A nonblank field can preserve that information, but cannot authenticate it. The user still needs to examine whether the source applies to the exact pump revision and condition.

A completed source field records a declaration; it does not authenticate the document or establish that its revision and operating conditions apply. Typing manufacturer without an examined document therefore satisfies formatting while leaving the evidence task unresolved.

A partial curve can support a limited in-range question

The separate illustrative partial curve gives 700 L/h at one meter,500 at 1.5 and 200 at two. The domain is explicitly one to two meters. For a required 300 L/h at total 1.8 meters, the relevant bracket is 1.5 to two.

The query lies 60 percent through that half-meter interval. Interpolated flow is 500+(200−500)×0.6=320 L/h, leaving 20 margin. The actual in-range run meets the supplied requirement.

This does not fill the rest of the curve. It supports one bounded reading under an explicitly declared source and condition. A partial document can be useful when the intended query lies inside its relevant supported range; incompleteness elsewhere does not automatically invalidate that scoped arithmetic.

Neither side of the domain permits an extension

Same illustrative partial source, different query locations
Total headLocationAvailable result
0.7 mBelow first sampleUnknown; Insufficient Data
1.8 mWithin 1–2 m support320 L/h
2.5 mAbove last sampleUnknown; Insufficient Data

The two additional actual runs preserve null available flow outside the domain. They do not extend the nearest line, even if a separate maximum-head statement might appear to leave room.

Below-range extrapolation is also prohibited. It may feel conservative to extend a decreasing line toward lower head, but that still invents unsupported values. The source's domain, not the owner's intuition about the direction of the trend, determines whether the numerical model can answer.

Two maxima do not reveal the local shape

Several different curves can share headline endpoints while differing at an intermediate head. Without applicable local information, a straight endpoint line is one invented possibility among others. Its precision does not make it evidence.

A pump curve is needed alongside system characteristics for duty analysis. Headline maxima cannot supply the missing local relation or the complete installed requirement. The household should seek the correct documentation rather than manufacture the graph it hoped to read.

The request should identify the exact candidate, revision and operating condition. A graph for another model or speed is not automatically a substitute. If the source is only a cropped region, preserve that domain and check whether the intended query genuinely lies within it.

Withholding the match is a complete decision when evidence is inadequate

For the headline-only candidate, the household should withhold a numerical match. It can obtain applicable curve evidence, consider a better-documented candidate or revise the reliance on a quantitative selection claim. No purchase recommendation is needed to complete that evidence decision.

For a genuinely applicable partial source covering the query, it can retain a scoped in-range result while leaving other conditions unknown. That is a more useful conclusion than either inventing a whole curve or dismissing all partial data as worthless.

The distinction also helps later review. A saved 320 L/h result should travel with the partial domain and source scope. Someone moving the query beyond two meters should see that the earlier calculation no longer applies, rather than reuse its favorable status as a permanent property of the candidate.

Preserve what a partial source actually covers

A partial source can contain a genuine supported local region while omitting headline endpoints. For the limited 1.8-meter query in this example, the adjacent 1.5 and two-meter samples are sufficient for the declared piecewise-linear reading. The absence of a zero-head sample is not itself a reason to invent one.

The source record should identify why that region applies: the exact pump identity, revision and operating condition, with the partial domain intact. A cropped image without those labels may fail the applicability question even when its numerical points look plausible. Domain support and source identity are separate requirements.

This helps avoid two opposite mistakes. The owner should not fill every missing point to make the document look complete. It also should not reject useful scoped evidence merely because the entire performance envelope is unavailable. The appropriate conclusion names the question that can be answered and leaves other questions open.

A missing numerical answer can still narrow the equipment decision

For the headline-only proposal, the next evidence request is specific: an applicable curve or sufficient supported local data at the intended condition. Repeating maximum flow and maximum head does not satisfy it. A response giving a neighboring revision should be kept separate until its applicability is established.

If no adequate source can be obtained, choosing a better-documented complete candidate may be reasonable for a household that needs a quantitative requirement check. That is an evidence-based shortlist criterion, not a claim that the undocumented candidate physically cannot work. Unknown and known failure remain different outcomes.

The actual out-of-range runs illustrate the same distinction. They do not return Does Not Meet because the available flow was not established. They return Insufficient Data with null available flow. A required point outside the supplied domain could ultimately pass or fail under better evidence; this partial curve does not decide it.

Keep that distinction when saving or sharing a comparison. A blank numerical result should not be converted into zero flow, and a formatted source label should not be converted into verified documentation. The useful result is the precise boundary of the available evidence.

Once appropriate data arrives, update the source and domain and rerun the actual query. Preserve the earlier insufficient result as history if needed, but do not describe the new result as proof that the old candidate changed performance. The evidence changed; the calculation can now answer a question it previously could not.

Let the evidence domain define the answer domain

The illustrative in-range query gives 320 L/h and 20 margin. The two out-of-range queries produce Insufficient Data, and the missing-source test produces no meaningful match. These outcomes reflect different evidence conditions, not contradictory pump performance.

The practical result is a bounded selection rule: no invented endpoint line, no unidentified defaults as real evidence and no extrapolation outside a partial source. Use the part of the curve that is genuinely supported and withhold the rest.

This keeps T12 useful when data is incomplete. It can expose the exact reason a result is unavailable and can perform a legitimate limited reading when the required support exists, without pretending to verify a source, a complete system intersection or actual hardware compatibility.

Sources and evidence scope

  1. Declared bounded pump-curve interpolation model — Declared mathematical model.

    The stated geometric and arithmetic rules are explained in this analysis and the related tool.. Supports: Static head plus supplied loss; adjacent-point linear interpolation in range; no extrapolation; current input and status rules.. Reviewed ; access basis: Current pure engine and catalog actually examined. All numeric curves and installed conditions are original illustrative declarations..

  2. Grundfos: Duty point — manufacturer technical explanation.

    Duty point definition and pump/system characteristic paragraphs. Supports: Conceptual distinction between a pump curve and the intersection with system characteristics; no numeric example curve supplied by this source.. Reviewed ; access basis: Complete short primary article opened and read; no manufacturer curve or hydroponic recommendation inferred..

This article uses sourced analysis and explicitly labeled scenarios. It does not report hands-on product testing or claim professional peer review.

Use the relevant tools

Background guides

Back to Cases