A Maximum-Head Statement Does Not Complete the Working-Curve Evidence
An illustrative owner sees a2.5-meter maximum-head endpoint and assumes a2.2-meter requirement should be comfortably inside it.
Evidence basis: Illustrative Scenario / Worked Example — invented declared curves, not real pump tests.
Updated
Decide what the supplier’s endpoint statement establishes
The buyer has a technical response quoting maximum head of 2.5 meters. The intended complete requirement is 250 L/h at 2.2 meters. The immediate decision is whether the response supplies adequate working-flow evidence, rather than whether 2.2 is numerically below 2.5.
The curve in this article is explicitly hypothetical. It defines its 2.5-meter endpoint as zero flow; that definition must not be assumed for an ambiguously labeled real document without reading its conditions. No commercial pump or installed operating record is represented here.
A supported endpoint can be retained as useful evidence while the selection question remains open. It identifies one head/flow condition and the end of this supplied table. It does not fill the intermediate curve, establish an approved operating envelope or turn 0.3 meters of head difference into a flow allowance. The following calculations show what additional local evidence contributes.
Read the near-end segment at the required condition
The proposed static rise is two meters and the supplied loss 0.2, giving 2.2 total. The curve gives 300 L/h at two meters and zero at 2.5. The query is 0.2 out of 0.5 meters through that interval, or 40 percent.
The bounded calculation gives 300+(0−300)×0.4=180 L/h. The margin against 250 is minus 70. The actual T12 run does not meet the supplied requirement, despite the head being below 2.5.
This is exactly the information the endpoint alone lacked. It establishes a curve-based result for this local condition. It does not establish that every pump near its maximum head behaves with the same slope.
At the endpoint, the declared curve supplies no working flow
The exact 2.5-meter run returns zero available flow and a negative 250 margin. No interpolation is necessary because the endpoint is supplied. That result gives the maximum-head statement its meaning within this hypothetical curve.
| Declared condition | Available flow | Margin against 250 L/h |
|---|---|---|
| 1.7 m alternative | 390 L/h | 140 L/h |
| 2.2 m proposal | 180 L/h | −70 L/h |
| 2.5 m supplied endpoint | 0 L/h | −250 L/h |
The endpoint should not be combined with the zero-head flow to create a claim that both maxima occur together. They belong to different locations on the curve. The household needs one working condition with both quantities identified.
A lower declared condition demonstrates the right question
The alternative arrangement declares 1.5 meters static and 0.2 loss, or 1.7 total. Between one meter at 600 L/h and two at 300, interpolation gives 390. The margin is 140 and the actual run meets the supplied requirement.
This is not an instruction to relocate the garden or alter plumbing. The alternative is a separate hypothesis that would need its own applicable design evidence. It demonstrates that the decision changes when the working condition changes, not when the maximum endpoint is renamed more generous.
The actual duty point relates pump and system characteristics. T12 checks a supplied condition, with loss appropriate to intended flow. It cannot decide where a real household system operates simply from the maximum head.
A missing local curve remains missing even with a clear maximum
If the owner has only the endpoint and no adequate intermediate evidence, it cannot reproduce the 180 or 390 figures for a real pump. A guessed straight line between maxima would create a new curve, not recover the manufacturer's missing data.
The correct request is a source-scoped curve for the exact pump and intended operating condition. A neighboring model or different speed can have a different relation. The owner should preserve identity and conditions rather than infer them from a familiar housing.
This case provides no optimum operating band, efficiency peak or minimum distance from shutoff. Those would need their own evidence. The supplied curve supports only the stated interpolation and requirement decision.
Find the head that supplies the required flow
The supplied maximum is 2.5 meters, but the declared 250 L/h requirement is reached earlier on the curve. Between two meters at 300 and 2.5 at zero, a 50 L/h drop is needed to reach 250. That is one sixth of the 300 L/h segment drop, corresponding to one sixth of the half-meter head interval.
The requirement threshold is therefore about 2.083 meters total head. An additional actual run at that calculated boundary gives 250 L/h with essentially zero numerical margin. The proposed 2.2 lies beyond the requirement threshold even though it remains below the zero-flow endpoint.
This is the correct use of the local curve for the owner's question. The distance between maximum head and required head is not itself the available-flow allowance. The local relation determines where the desired 250 is supported.
If the static rise and loss are both justified, the owner can compare their sum with the requirement threshold. It should not turn that comparison into a recommended installation height or a permitted maximum. The hypothetical curve has no hardware identity or physical operating approval, and equality does not establish robustness.
The threshold also changes when required flow changes. A different receiving requirement would meet the same curve at another point. Maximum head remains the same in the illustrative table while the relevant working decision changes. That is why a single endpoint cannot answer every intended use.
Accept the endpoint for its limited claim; request the missing curve
A supplier answer quoting only maximum head can close a narrow endpoint question when its definition, model and conditions are clear. It does not close the required 250 L/h-at-2.2-meter question. The buyer should retain that answer at its original scope and ask for applicable flow/head data covering the intended region. Rejecting the stronger inference does not require discarding the valid endpoint statement.
Do not build a straight line between a quoted zero-head maximum flow and maximum head merely because two numbers are available. That line would be a newly invented curve. The 180 L/h calculation above is possible because this example independently supplies the adjacent two-meter/300 L/h and 2.5-meter/zero samples. Those local samples, rather than the maximum label alone, support interpolation.
The source must also establish which operating state the data describes. Model revision, speed and stated fluid or test conditions cannot be replaced by a familiar product name. If another document supplies a different variant, keep it separate until its applicability is established. More endpoint precision would not repair an identity mismatch.
Coverage is a second evidence gate. T12 accepts the declared 2.5-meter endpoint because it is supplied. It refuses a query beyond the supplied curve domain rather than extend the last segment. An incomplete table ending before an intended query would likewise leave the calculation unsupported; it would not establish zero available flow at every later head. Missing coverage and a supplied zero-flow point are different facts.
Finally, an arithmetic match at 2.083 meters or a supplied zero at 2.5 is not permission to operate equipment at either condition. This example contains no permitted operating range, efficiency, minimum-flow instruction or continuous-shutoff approval. Those are separate source questions. The buyer can accept the table for its stated mathematical evidence while keeping actual use subject to the exact equipment’s documentation.
The resulting evidence request is specific: an applicable local curve covering the complete intended requirement, plus the equipment’s permitted operating conditions. An answer repeating only the endpoint remains useful for its endpoint claim and insufficient for the working requirement. That distinction gives the buyer a clear stopping rule for the inquiry without inventing a universal fraction of maximum head.
Close the working evidence gap before accepting the proposal
Under the supplied local curve, the 2.2-meter proposal provides 180 L/h and misses the 250 requirement. The separate 1.7-meter declaration provides 390 and passes; the 2.5-meter supplied endpoint gives zero. Keep each scoped result rather than summarize the document as simply capable of 2.5 meters.
A real response containing only maximum head should be filed as partial evidence. Obtain the correct local curve and complete requirement before issuing a working-flow acceptance. If the available table does not cover the intended query, withhold a numerical result rather than extrapolate or substitute a neighboring model.
The practical decision is whether the available documentation answers the actual working question. Endpoint evidence, intermediate flow evidence and permitted operation need separate support. Keeping them separate prevents a technically valid maximum statement from becoming an unsupported selection approval.
Sources and evidence scope
- Declared bounded pump-curve interpolation model — Declared mathematical model.
The stated geometric and arithmetic rules are explained in this analysis and the related tool.. Supports: Static head plus supplied loss; adjacent-point linear interpolation in range; no extrapolation; current input and status rules.. Reviewed ; access basis: Current pure engine and catalog actually examined. All numeric curves and installed conditions are original illustrative declarations..
- Grundfos: Duty point — manufacturer technical explanation.
Duty point definition and pump/system characteristic paragraphs. Supports: Conceptual distinction between a pump curve and the intersection with system characteristics; no numeric example curve supplied by this source.. Reviewed ; access basis: Complete short primary article opened and read; no manufacturer curve or hydroponic recommendation inferred..
This article uses sourced analysis and explicitly labeled scenarios. It does not report hands-on product testing or claim professional peer review.